{"id":453,"date":"2024-10-01T13:05:53","date_gmt":"2024-10-01T13:05:53","guid":{"rendered":"http:\/\/castco.wpenginepowered.com\/?post_type=ht_kb&#038;p=453"},"modified":"2024-12-06T17:56:29","modified_gmt":"2024-12-06T17:56:29","slug":"hanna-checker-phosphate-low-range","status":"publish","type":"ht_kb","link":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/","title":{"rendered":"Method audit: Phosphate \u2013 Hanna Checker"},"content":{"rendered":"\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading\">Overview of the Hanna Checker \u2013 Phosphate (low range) <\/h3>\n\n\n\n<p>The <a href=\"https:\/\/www.hannainstruments.co.uk\/photometers\/790- pocket-checker-for-phosphate-testing\" target=\"_blank\" rel=\"noreferrer noopener\">Hanna HI-713<\/a> is a small handheld colorimeter that measures phosphate in water. A chemical reagent is added to a water sample in a 10mL glass sample vial. In the presence of phosphate the sample changes to a blue colour, by measuring the degree of colour change the colorimeter can determine the concentration of phosphate in the sample.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"811\" data-src=\"https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png\" alt=\"\" class=\"wp-image-1093 lazyload\" data-srcset=\"https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png 1024w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-640x507.png 640w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-768x608.png 768w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-50x40.png 50w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26.png 1192w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/811;\" \/><\/figure>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-image alignleft size-thumbnail\"><a href=\"https:\/\/castco.org\/knowledge-base\/monitoring-purpose\/\" target=\"_blank\" rel=\" noreferrer noopener\"><img decoding=\"async\" width=\"150\" height=\"150\" data-src=\"https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/surveillance-inv-eval-150x150.png\" alt=\"\" class=\"wp-image-2165 lazyload\" data-srcset=\"https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/surveillance-inv-eval-150x150.png 150w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/surveillance-inv-eval-640x640.png 640w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/surveillance-inv-eval-768x768.png 768w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/surveillance-inv-eval-50x50.png 50w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/surveillance-inv-eval.png 921w\" data-sizes=\"(max-width: 150px) 100vw, 150px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 150px; --smush-placeholder-aspect-ratio: 150\/150;\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-thumbnail\"><a href=\"https:\/\/castco.org\/knowledge-base\/monitoring-purpose\/\" target=\"_blank\"><img decoding=\"async\" width=\"150\" height=\"150\" data-src=\"https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/tiers-1-2-2-150x150.png\" alt=\"\" class=\"wp-image-2166 lazyload\" data-srcset=\"https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/tiers-1-2-2-150x150.png 150w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/tiers-1-2-2-640x640.png 640w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/tiers-1-2-2-1024x1024.png 1024w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/tiers-1-2-2-768x768.png 768w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/tiers-1-2-2-50x50.png 50w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/tiers-1-2-2-1280x1280.png 1280w, https:\/\/castco.org\/wp-content\/uploads\/2024\/10\/tiers-1-2-2.png 1329w\" data-sizes=\"(max-width: 150px) 100vw, 150px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 150px; --smush-placeholder-aspect-ratio: 150\/150;\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Suitability for monitoring purposes<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Monitoring purpose category<\/strong><\/td><td><strong>Likely Tier(s)<\/strong><\/td><td><strong>Suitability<\/strong><\/td><\/tr><tr><td>Engagement: Education and raising awareness<\/td><td>0-1<\/td><td>\u2716<\/td><\/tr><tr><td>Surveillance: Ecosystem health screening<\/td><td>1 (2)<\/td><td>\u2713<\/td><\/tr><tr><td>Investigation: Helping to target further action<\/td><td>2 (3)<\/td><td>\u2713<\/td><\/tr><tr><td>Evaluation: Assessing the impact of actions<\/td><td>2 (3)<\/td><td>\u2713<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p><span style=\"box-sizing: border-box; margin: 0px; padding: 0px;\"><strong>Details:&nbsp;<\/strong>The low-range device measures phosphate in the range of 0 \u2013 2.50 ppm as PO<sub>4<\/sub>.<\/span> Accuracy is stated as &#8216;+\/- 0.04 ppm +\/- 4% of reading (at 25\u00b0C).<\/p>\n\n\n\n<p><strong>Data System:<\/strong> N\/A. Results are not stored on the device, so the user must record and store them. CaSTCo is developing guidance for the recording, formatting and sharing of data.<\/p>\n\n\n\n<p><strong>Cost:<\/strong> LOW. Around \u00a385, including VAT for the instrument, and then \u00a317 for 25 tests (\u00a30.68\/test).<\/p>\n\n\n\n<p><strong>Ease of use<\/strong>: MEDIUM. The Hanna HI-713 requires users to handle reagents, dispense an accurate sample volume, and ensure vials are clean and condensation-free. Instructions are provided, and video guides are available.<\/p>\n\n\n\n<p><strong>Quality control: <\/strong>Local coordinators are responsible for quality control. Measurement is likely affected by extremes of temperature and turbidity, so a good idea to measure and record those alongside the phosphate measurement if possible. CaSTCo is developing guidance and templates to help with data QA\/QC.<\/p>\n\n\n\n<p><strong>Coverage \/ scale<\/strong>: This can be used anywhere. It is currently used by many local\/regional groups and as part of the Angling Trust Water Quality Monitoring Network nationally.<\/p>\n\n\n\n<p><strong>Health &amp; safety<\/strong>: The reagent used is toxic if inhaled and can cause severe skin burns and eye damage, so care must be taken when handling. The Safety Data Sheet is available for download from <a href=\"https:\/\/sds.hannainst.com\/\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/sds.hannainst.com\/<\/a>. CaSTCo is developing appropriate health and safety guidance.<\/p>\n\n\n\n<p><strong>CaSTCo Investment:<\/strong> CaSTCo is reviewing and investing in this method to optimise data quality, ease of use, safety and cost, including rolling out training and investing in data systems.<\/p>\n\n\n\n<p><strong>Case study featuring this method<\/strong>: <a href=\"https:\/\/castco.org\/case-study\/wensum-catchment\/\">Wensum Catchment: citizen science helps resolve pollution issue<\/a><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Overview of the Hanna Checker \u2013 Phosphate (low range) The Hanna HI-713 is a small handheld colorimeter that measures phosphate in water. A chemical reagent&#8230;<\/p>\n","protected":false},"author":2,"comment_status":"closed","ping_status":"closed","template":"","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"ht-kb-category":[34],"ht-kb-tag":[],"class_list":["post-453","ht_kb","type-ht_kb","status-publish","format-standard","hentry","ht_kb_category-water-quality-methods"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Method audit: Phosphate \u2013 Hanna Checker - CastCo<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Method audit: Phosphate \u2013 Hanna Checker - CastCo\" \/>\n<meta property=\"og:description\" content=\"Overview of the Hanna Checker \u2013 Phosphate (low range) The Hanna HI-713 is a small handheld colorimeter that measures phosphate in water. A chemical reagent...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/\" \/>\n<meta property=\"og:site_name\" content=\"CastCo\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-06T17:56:29+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/castco.org\\\/knowledge-base\\\/hanna-checker-phosphate-low-range\\\/\",\"url\":\"https:\\\/\\\/castco.org\\\/knowledge-base\\\/hanna-checker-phosphate-low-range\\\/\",\"name\":\"Method audit: Phosphate \u2013 Hanna Checker - CastCo\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/castco.org\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/castco.org\\\/knowledge-base\\\/hanna-checker-phosphate-low-range\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/castco.org\\\/knowledge-base\\\/hanna-checker-phosphate-low-range\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/castco.org\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png\",\"datePublished\":\"2024-10-01T13:05:53+00:00\",\"dateModified\":\"2024-12-06T17:56:29+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/castco.org\\\/knowledge-base\\\/hanna-checker-phosphate-low-range\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/castco.org\\\/knowledge-base\\\/hanna-checker-phosphate-low-range\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/castco.org\\\/knowledge-base\\\/hanna-checker-phosphate-low-range\\\/#primaryimage\",\"url\":\"http:\\\/\\\/castco.org\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png\",\"contentUrl\":\"http:\\\/\\\/castco.org\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/castco.org\\\/knowledge-base\\\/hanna-checker-phosphate-low-range\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/castco.org\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Method audit: Phosphate \u2013 Hanna Checker\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/castco.org\\\/#website\",\"url\":\"https:\\\/\\\/castco.org\\\/\",\"name\":\"CaSTCo\",\"description\":\"Catchment Systems Thinking Cooperative\",\"publisher\":{\"@id\":\"https:\\\/\\\/castco.org\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/castco.org\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/castco.org\\\/#organization\",\"name\":\"CaSTCo\",\"url\":\"https:\\\/\\\/castco.org\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/castco.org\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"http:\\\/\\\/castco.org\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/castco-1.png\",\"contentUrl\":\"http:\\\/\\\/castco.org\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/castco-1.png\",\"width\":1500,\"height\":573,\"caption\":\"CaSTCo\"},\"image\":{\"@id\":\"https:\\\/\\\/castco.org\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Method audit: Phosphate \u2013 Hanna Checker - CastCo","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/","og_locale":"en_US","og_type":"article","og_title":"Method audit: Phosphate \u2013 Hanna Checker - CastCo","og_description":"Overview of the Hanna Checker \u2013 Phosphate (low range) The Hanna HI-713 is a small handheld colorimeter that measures phosphate in water. A chemical reagent...","og_url":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/","og_site_name":"CastCo","article_modified_time":"2024-12-06T17:56:29+00:00","og_image":[{"url":"http:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/","url":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/","name":"Method audit: Phosphate \u2013 Hanna Checker - CastCo","isPartOf":{"@id":"https:\/\/castco.org\/#website"},"primaryImageOfPage":{"@id":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/#primaryimage"},"image":{"@id":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/#primaryimage"},"thumbnailUrl":"http:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png","datePublished":"2024-10-01T13:05:53+00:00","dateModified":"2024-12-06T17:56:29+00:00","breadcrumb":{"@id":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/#primaryimage","url":"http:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png","contentUrl":"http:\/\/castco.org\/wp-content\/uploads\/2024\/10\/Screenshot-on-2024-10-30-at-22-47-26-1024x811.png"},{"@type":"BreadcrumbList","@id":"https:\/\/castco.org\/knowledge-base\/hanna-checker-phosphate-low-range\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/castco.org\/"},{"@type":"ListItem","position":2,"name":"Method audit: Phosphate \u2013 Hanna Checker"}]},{"@type":"WebSite","@id":"https:\/\/castco.org\/#website","url":"https:\/\/castco.org\/","name":"CaSTCo","description":"Catchment Systems Thinking Cooperative","publisher":{"@id":"https:\/\/castco.org\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/castco.org\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/castco.org\/#organization","name":"CaSTCo","url":"https:\/\/castco.org\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/castco.org\/#\/schema\/logo\/image\/","url":"http:\/\/castco.org\/wp-content\/uploads\/2024\/10\/castco-1.png","contentUrl":"http:\/\/castco.org\/wp-content\/uploads\/2024\/10\/castco-1.png","width":1500,"height":573,"caption":"CaSTCo"},"image":{"@id":"https:\/\/castco.org\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/castco.org\/json\/wp\/v2\/ht-kb\/453","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/castco.org\/json\/wp\/v2\/ht-kb"}],"about":[{"href":"https:\/\/castco.org\/json\/wp\/v2\/types\/ht_kb"}],"author":[{"embeddable":true,"href":"https:\/\/castco.org\/json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/castco.org\/json\/wp\/v2\/comments?post=453"}],"version-history":[{"count":0,"href":"https:\/\/castco.org\/json\/wp\/v2\/ht-kb\/453\/revisions"}],"wp:attachment":[{"href":"https:\/\/castco.org\/json\/wp\/v2\/media?parent=453"}],"wp:term":[{"taxonomy":"ht_kb_category","embeddable":true,"href":"https:\/\/castco.org\/json\/wp\/v2\/ht-kb-category?post=453"},{"taxonomy":"ht_kb_tag","embeddable":true,"href":"https:\/\/castco.org\/json\/wp\/v2\/ht-kb-tag?post=453"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}